=== EMERGENCY SKILLS CHEATSHEET ===
Drill getting on and off the loop 100 times each. When reversing skills always turn on O2 and check po2 in the loop before getting on the loop.
[ GET OFF THE LOOP — VVIP ]
- Grab loop with left hand
- Left hand with canister needs to have the canister pointing down and away from the other divers
- Breathe in
- Close the dsv - DOWN
[ GET ON THE LOOP — VVIP ]
- Grab the loop with left hand
- Left hand with canister needs to have the canister pointing down and away from the other divers
- Purge water until bubbles come
- Open the dsv - UP
[ VERIFY O2 → OPEN ]
When in doubt verify O2 is OPEN
- CLOSE O2
- OPEN O2
- Signal O2 OPEN
[ TIMEOUT ]
- Signal
- Get off the loop (grab loop [light facing down] and close dsv) onto the short hose
- Turn O2 off and signal O2 off
[ BAILOUT ]
- Timeout
- Switch computer to bailout
- Signal switch
- Signal loop broken
- Signal ascent
[ GURGLE LEFT ]
- Bailout
[ GURGLE RIGHT ]
- Pull loop close together
- Blow hard a few times to push the water down the side
- Stretch and hold the loop up to get the water to flow down to the canisters
[ S-DRILL ]
- Unclip long hose
- Grab loop with light down and close dsv
- Hold loop over head
- Duck and punch long hose to victim
- Purge gas out of mouth piece and then open dsv
[ HYPERCAPNIA ]
- Bailout
[ HYPOXIA ]
- Timeout
- Think
- Open O2
- Signal O2 open
- Check O2 pressure using MAV
- Signal O2 pressure okay if okay
- Check PO2
- Signal O2 okay but going to Chicken
- Chicken: push down opv while rolling to the right. This floods the loop with breathable gas.
- Get on the loop
- Signal computer po2 okay
- Signal ccr okay
[ HYPEROXIA ]
- Timeout
- Double check O2 closed
- Signal O2 closed
- Check if the mav button is stuck, try to fix it
- Signal it is fixed
- Chicken wing a diluent flush
- Once you have breathable gas signal you are getting back on the loop even though you remember O2 is closed
- Keep an eye on the computer
- Slowly open O2, making sure there's no boom
- Signal okay if it works
[ CELL VERIFICATION ]
- Signal
- Tell team computer is not okay
- O2 closed
- Signal O2 closed
- Purge mav O2
- Mouth to nose bring po2 to Dil po2
- Signal which cell is broken
[ INTERNAL BOOM → O2 ]
- You feel pressure inside the unit
- Vent to stay level
- Signal
- Turn off O2 immediately - hand on tank until the boom is done
- Hand on mav - Diluent flush
- Bring it to something breathable
- Signal O2 not okay
- O2 broken
- Call the dive
[ EXTERNAL BOOM → O2 ]
- You feel a leak on the O2 cylinders first stage
- Turn off O2 while signaling
- Ask buddy to check the O2 tank
- Verify O2 is open after check